Comment 1 to 9 of 9 Page: 1 |
|
|||
Decent gear that. Probably get a more exact date from the series cap - no doubt has it's manufacture date printed on it somewhere.
|
|
|||
Guessing it was the later ones that had the 2 separate ballasts in series then?
|
|
|||
interesting! I would say this is actually an earlier one, pre-dating the series ballasts, but most this early have black coloured ones, this must be a fairly rare transitional fixture, all white etc but still single choke, it would be interesting to see what the date on the series cap is as Slyspark says
|
|
|||
Yup, the series ones came after this - they used the open frame type that followed this potted version.
|
|
|||
The series ones was a better setup!
|
|
|||
the series capacitor is dated 12/71
|
|
|||
Cool! So, probably somewhere around 53yrs old then.... Best that LED!
|
|
|||
How the series capacitor boosts the OCV of the ballast from the mains 240V to 440V which is enough to start krypton 100W T12?
|
|
|||
it does not boost the OCV, nor is it required for a Krypton 100W T12, in fact those tubes can explictly be run without a capacitor, and its why a lot of later 8ft British fixtures are for 100W tubes only since they lack the series capacitor that a 125W Argon 8ft T12 tube needs to run if on 240V mains
|