Experiment ended 
My N817 test ended this morning, and this is the result of one start and 2174 hrs in 90 days!, you can see how much emitter is still on the cathodes though, even after 2000+ run hours, when their not being started every night!
This batch has now been tested 3 different ways, and the conclusion is they are indeed a manufacturing fault!

Experiment ended

My N817 test ended this morning, and this is the result of one start and 2174 hrs in 90 days!, you can see how much emitter is still on the cathodes though, even after 2000+ run hours, when their not being started every night!
This batch has now been tested 3 different ways, and the conclusion is they are indeed a manufacturing fault!

DSCF1377.jpg Screenshot_20210822-122155.jpg BC406934-9DA3-4F01-96BC-5752485C1110.jpeg IMG_20210816_144915827.jpg DSC07151.JPG
File information
Filename:BC406934-9DA3-4F01-96BC-5752485C1110.jpeg
Album name:AngryHorse / Sodium lamps, (low pressure).
Date manufactured:January 2003
Filesize:2699 KiB
Date added:21 Aug, 2021
Dimensions:2730 x 2048 pixels
Displayed:19 times
URL:http://80.229.24.59:9232/gallery/displayimage.php?pid=16249
Favourites:Add to Favourites

Comment 1 to 2 of 2
Page: 1

Danny   [23 Aug, 2021 at 08:28 PM]
90 days! Worst lamp of the whole batch surely
AngryHorse   [23 Aug, 2021 at 08:46 PM]
Possibly?