CH lighting F10T8/D
10w dinky tubes running on a Harvard DKE 13 (7-13w D/D/DD/T5) UK made elctronic ballast (each has their own ballast)
The other tube died without me knowing,hence one new one & one banded like a bitch. Wattage drawn for a single tube is 9. something watts

CH lighting F10T8/D

10w dinky tubes running on a Harvard DKE 13 (7-13w D/D/DD/T5) UK made elctronic ballast (each has their own ballast)
The other tube died without me knowing,hence one new one & one banded like a bitch. Wattage drawn for a single tube is 9. something watts

YK1.jpg Photo_19-09-20262C_12_58_03_28129.jpg 20260925_004014.jpg 20260924_164039.jpg 1000106072.jpg
File information
Filename:20260925_004014.jpg
Album name:Arrowslim / T10 tubes
Filesize:2727 KiB
Date added:25 Sep, 2026
Dimensions:1536 x 2048 pixels
Displayed:15 times
URL:http://80.229.24.59:9232/gallery/displayimage.php?pid=25647
Favourites:Add to Favourites

Comment 1 to 4 of 4
Page: 1

Danny   [25 Sep, 2026 at 09:03 PM]
The banded one is lovely
Arrowslim   [25 Sep, 2026 at 09:43 PM]
yeah, it took a while, I think they are a little under run.. shame I missed the one that died..
Lightbulbfun   [26 Sep, 2026 at 02:26 AM]
Yeah 10W T8's run at 46V 230mA so depending on the exact specifics of the HF ballast may be a little under-run on a 13W PL HF ballast some nice banding tho, how did the other one die, did it also band up, then sock up or did it die in another way? how many hours do they run? is it 247 or are there some switching cycles involved? Smile

im guessing this was once of those cheap battery emergency lights with the sealed lead acid battery in that eats tubes? (edit: just seen your other upload on these tubes that the fixture was just that !)
Arrowslim   [26 Sep, 2026 at 06:14 AM]
they were ran 24-7, the other one banded up. when it died, both ends socked & cathodes both open circuit so guess it went out well..