tubes ok. I revive my GEC 80 watt fluorescent tube that fail to start in my light pack. where ever this ballast went to. It suppose to go to Danny to light His American F72T12 single pin slimeline lamps.
Advance now makes HO output sign ballast like this with 800 Ma drive current per lamp. since they banned magnetic Sign ballast. plus it make things bit easer on my last sign job as wireing for HO magnetic was bit fucked and cant reach to of sign to rewire and replace lamp holders. those HF ballast work nicely coverting them over. it also when it only time the magnetic gear sucks. getting 7 to 9 months on a philip lamps going pink and dim. the same batch of lamp lasted much longer on Switch starts